Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Periodontal & Implant Science ; : 58-58, 2019.
Article in English | WPRIM | ID: wpr-766086

ABSTRACT

This article has been retracted at the request of the Editor-in-Chief, because the authors plagiarized a previously published paper that had appeared in: Int J Oral Maxillofac Implants, 26 (2011) 101–107. This article presented the same table and figures as the original study, and changed 2 of the tables to figures. This article reflects severe abuse of the scientific publishing system, and has therefore been retracted.


Subject(s)
Humans , Bacterial Adhesion , Colon , Titanium
2.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 352-357, 2016.
Article in English | WPRIM | ID: wpr-27964

ABSTRACT

OBJECTIVES: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. MATERIALS AND METHODS: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. RESULTS: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. CONCLUSION: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.


Subject(s)
Grassland , Maxillofacial Prosthesis , Prostheses and Implants , Prosthesis Failure , Prosthesis Retention , Torque
3.
Journal of Periodontal & Implant Science ; : 217-223, 2012.
Article in English | WPRIM | ID: wpr-188642

ABSTRACT

PURPOSE: Several parameters have been described for determining the success or failure of dental implants. The surface properties of transgingival implant components have had a great impact on the long-term success of dental implants. The purpose of this study was to compare the tendency of two periodontal pathogens to adhere to and colonize zirconia abutments and titanium alloys both in hard surfaces and soft tissues. METHODS: Twelve patients participated in this study. Three months after implant placement, the abutments were connected. Five weeks following the abutment connections, the abutments were removed, probing depth measurements were recorded, and gingival biopsies were performed. The abutments and gingival biopsies taken from the buccal gingiva were analyzed using real-time polymerase chain reaction to compare the DNA copy numbers of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and total bacteria. The surface free energy of the abutments was calculated using the sessile water drop method before replacement. Data analyses used the Mann Whitney U-test, and P-values below 0.05 find statistical significance. RESULTS: The present study showed no statistically significant differences between the DNA copy numbers of A. actinomycetemcomitans, P. gingivalis, and total bacteria for both the titanium and zirconia abutments and the biopsies taken from their buccal gingiva. The differences between the free surface energy of the abutments had no influence on the microbiological findings. CONCLUSIONS: Zirconia surfaces have comparable properties to titanium alloy surfaces and may be suitable and safe materials for the long-term success of dental implants.


Subject(s)
Humans , Alloys , Bacteria , Bacterial Adhesion , Biopsy , Coat Protein Complex I , Colon , Dental Abutments , Dental Implants , DNA , Gingiva , Porphyromonas gingivalis , Real-Time Polymerase Chain Reaction , Statistics as Topic , Surface Properties , Titanium , Water , Zirconium
SELECTION OF CITATIONS
SEARCH DETAIL